[{"data":1,"prerenderedAt":194},["ShallowReactive",2],{"service-power-solutions":3,"service-content-power-solutions":17},{"id":4,"menu_type_id":5,"parent_id":6,"is_child":7,"menu_title":8,"page_title":8,"icon":9,"slug":10,"link":11,"content":11,"page_banner":12,"menu_order":5,"meta_tag":11,"meta_title":11,"meta_description":8,"status":13,"publish_date":9,"expire_date":9,"created_at":14,"created_by":7,"updated_at":15,"updated_by":16},"10","3","2","1","Power Solutions",null,"power-solutions","","916826_613996.jpg","Live","2021-08-08 01:54:02","2022-02-23 05:11:12","4)",{"title":8,"tagline":18,"description":19,"intro":20,"introDetail":21,"stats":22,"features":32,"scopeItems":41,"items":50,"flagship":113,"processSteps":129,"standards":154,"processTitle":171,"processSubtitle":172,"standardsTitle":173,"standardsIntro":174,"faq":175},"Supply · Installation · Maintenance","ICSTECH delivers complete power infrastructure on a turnkey basis: engineered, installed, tested and maintained by certified experts.","ICSTECH provides **supply, installation & maintenance** of power systems for telecom operators, utilities, industries, real estate and government projects across Bangladesh. Our power division combines electrical engineering expertise with project management discipline - from sub-station design and generator installation to lifts, telecom UPS (AC & DC), solar systems, PFI plants and CC camera security.","Every project is executed with strict HSE compliance, OEM-sourced equipment, full testing & commissioning documentation, and backed by 24\u002F7 operations and maintenance support - the same delivery standard proven on the Ruppur–Gopalganj 400kV transmission line.",[23,26,29],{"value":24,"label":25},"400kV","Transmission Level",{"value":27,"label":28},"8+","Power Verticals",{"value":30,"label":31},"24\u002F7","O&M Support",[33,35,37,39],{"text":34},"Single-point responsibility - design, supply, install, test & maintain under one contract.",{"text":36},"Certified electrical engineers and trained field crews with nationwide coverage.",{"text":38},"OEM partnerships for transformers, UPS, generators, lifts and solar equipment.",{"text":40},"AMC & warranty support with preventive maintenance schedules and rapid response.",[42,43,44,45,46,47,48,49],"Sub-Station","Generator","Lift \u002F Elevator","Telecom UPS (AC & DC)","Solar Systems","PFI Plant","CC Camera","Transmission Tower Installation",[51,59,66,74,82,89,97,105],{"name":42,"description":52,"color":53,"icon":54,"subItems":55},"Design, construction and commissioning of 11\u002F33\u002F132\u002F400kV substations - transformers, switchgear, protection & control panels.","amber","\u003Crect x='3' y='7' width='18' height='13' rx='2'\u002F\u002F>\u003Cpath d='M8 7V5a2 2 0 0 1 2-2h4a2 2 0 0 1 2 2v2'\u002F\u002F>\u003Cpath d='M12 11v5'\u002F\u002F>",[56,57,58],"Turnkey EPC execution","Protection & relay coordination","Preventive maintenance \u002F AMC",{"name":43,"description":60,"color":53,"icon":61,"subItems":62},"Supply & installation of diesel generators with ATS\u002FAMF panels, soundproof enclosures and fuel systems for standby power.","\u003Cpolygon points='13 2 3 14 12 14 11 22 21 10 12 10 13 2'\u002F\u002F>",[63,64,65],"Load sizing & site survey","ATS \u002F AMF synchronization","Scheduled servicing & overhaul",{"name":44,"description":67,"color":68,"icon":69,"subItems":70},"Passenger, goods & escalator solutions - installation, modernization of aging lifts and comprehensive AMC programs.","brand","\u003Crect x='5' y='2' width='14' height='20' rx='2'\u002F\u002F>\u003Cpolyline points='9 10 12 7 15 10'\u002F\u002F>\u003Cline x1='12' y1='7' x2='12' y2='17'\u002F\u002F>",[71,72,73],"New installation & commissioning","Modernization & retrofit","24\u002F7 breakdown response",{"name":45,"description":75,"color":76,"icon":77,"subItems":78},"Online AC UPS and −48V DC power plants for BTS sites, exchanges and data centers - with rectifiers and battery banks.","cyan","\u003Crect x='1' y='6' width='18' height='12' rx='2'\u002F\u002F>\u003Cline x1='23' y1='10' x2='23' y2='14'\u002F\u002F>\u003Cpolygon points='11 8.5 7.5 13 10.5 13 9.5 16.5 13.5 11.5 10.5 11.5'\u002F\u002F>",[79,80,81],"1kVA – 200kVA online UPS","DC power plant & rectifiers","Battery health management",{"name":46,"description":83,"color":53,"icon":84,"subItems":85},"Rooftop, hybrid & industrial solar plants with net-metering, monitoring and green energy compliance support.","\u003Ccircle cx='12' cy='12' r='4.5'\u002F\u002F>\u003Cline x1='12' y1='1.5' x2='12' y2='4'\u002F\u002F>\u003Cline x1='12' y1='20' x2='12' y2='22.5'\u002F\u002F>\u003Cline x1='4.2' y1='4.2' x2='6' y2='6'\u002F\u002F>\u003Cline x1='18' y1='18' x2='19.8' y2='19.8'\u002F\u002F>\u003Cline x1='1.5' y1='12' x2='4' y2='12'\u002F\u002F>\u003Cline x1='20' y1='12' x2='22.5' y2='12'\u002F\u002F>\u003Cline x1='4.2' y1='19.8' x2='6' y2='18'\u002F\u002F>\u003Cline x1='18' y1='6' x2='19.8' y2='4.2'\u002F\u002F>",[86,87,88],"Net-metering & hybrid setups","Remote performance monitoring","Panel cleaning & O&M",{"name":47,"description":90,"color":91,"icon":92,"subItems":93},"Power factor improvement plants - capacitor banks and APFC panels that cut utility penalties and improve efficiency.","emerald","\u003Cpolyline points='22 12 18 12 15 21 9 3 6 12 2 12'\u002F\u002F>",[94,95,96],"APFC panel design & supply","Harmonic analysis & filtering","PF audit & bill savings report",{"name":48,"description":98,"color":99,"icon":100,"subItems":101},"IP surveillance, NVR\u002FDVR, video walls and access control - powered and protected with dedicated UPS backup.","sky","\u003Cpath d='M23 19a2 2 0 0 1-2 2H3a2 2 0 0 1-2-2V8a2 2 0 0 1 2-2h4l2-3h6l2 3h4a2 2 0 0 1 2 2z'\u002F\u002F>\u003Ccircle cx='12' cy='13' r='4'\u002F\u002F>",[102,103,104],"Site survey & coverage design","Remote & mobile monitoring","Integrated power backup",{"name":49,"description":106,"color":107,"icon":108,"subItems":109},"Tower erection, conductor stringing and commissioning for power and telecom transmission lines nationwide.","indigo","\u003Cpath d='M12 3v18'\u002F\u002F>\u003Cpath d='M7 21l5-18 5 18'\u002F\u002F>\u003Cpath d='M8.5 14h7'\u002F\u002F>\u003Cpath d='M9.6 9h4.8'\u002F\u002F>",[110,111,112],"Foundation & erection","Stringing & sagging","Strict HSE field compliance",{"title":114,"description":115,"stats":116,"link":128},"Ruppur–Gopalganj 400kV Transmission Line","Design, supply, installation, testing & commissioning of the Ruppur–Gopalganj 400kV single circuit transmission line on a turnkey basis - proof of our capability to execute the highest-voltage power infrastructure projects in Bangladesh.",[117,119,122,125],{"value":24,"label":118},"Voltage",{"value":120,"label":121},"1-Ckt","Single Circuit",{"value":123,"label":124},"EPC","Turnkey",{"value":126,"label":127},"A→Z","Design to T&C","\u002F#projects",[130,134,138,142,146,150],{"step":131,"title":132,"description":133},"01","Load Survey","Demand analysis, site survey and feasibility report.",{"step":135,"title":136,"description":137},"02","Engineering Design","Single-line diagrams, layouts, BOQ and approvals.",{"step":139,"title":140,"description":141},"03","Supply","OEM-sourced equipment with logistics & customs handling.",{"step":143,"title":144,"description":145},"04","Installation","Certified crews, HSE compliance, quality checkpoints.",{"step":147,"title":148,"description":149},"05","Testing & Commissioning","Relay, load & acceptance tests with full documentation.",{"step":151,"title":152,"description":153},"06","O&M \u002F AMC","24\u002F7 monitoring, preventive maintenance, rapid response.",[155,159,163,167],{"title":156,"description":157,"color":68,"icon":158},"HSE Management","Site safety plans, PPE protocols and toolbox talks on every project.","\u003Cpath d='M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z'\u002F\u002F>",{"title":160,"description":161,"color":76,"icon":162},"IEC \u002F IEEE Standards","Design & testing aligned with international electrical codes.","\u003Cpath d='M14 2H6a2 2 0 0 0-2 2v16a2 2 0 0 0 2 2h12a2 2 0 0 0 2-2V8z'\u002F\u002F>\u003Cpolyline points='14 2 14 8 20 8'\u002F\u002F>\u003Cline x1='16' y1='13' x2='8' y2='13'\u002F\u002F>\u003Cline x1='16' y1='17' x2='8' y2='17'\u002F\u002F>",{"title":164,"description":165,"color":53,"icon":166},"Certified Engineers","Licensed electrical engineers sign off every design & test report.","\u003Ccircle cx='12' cy='8' r='6'\u002F\u002F>\u003Cpath d='M15.477 12.89 17 22l-5-3-5 3 1.523-9.11'\u002F\u002F>",{"title":168,"description":169,"color":91,"icon":170},"Quality Assurance","Multi-stage inspection, FAT\u002FSAT and as-built documentation.","\u003Cpath d='M22 11.08V12a10 10 0 1 1-5.93-9.14'\u002F\u002F>\u003Cpolyline points='22 4 12 14.01 9 11.01'\u002F\u002F>","How your power project is delivered","A disciplined six-phase turnkey process - the same methodology proven on national-grid transmission projects.","Engineered to code. Executed with zero compromise.","Power infrastructure demands absolute discipline. Every ICSTECH project follows international engineering standards, national grid codes and a strict HSE management system - protecting people, assets and uptime.",[176,179,182,185,188,191],{"question":177,"answer":178},"Do you provide turnkey solutions including design and approvals?","Yes. We handle the complete cycle - feasibility and load survey, engineering design, regulatory\u002Futility approvals support, supply, installation, testing & commissioning, and O&M. You get single-point responsibility from concept to energization.",{"question":180,"answer":181},"What voltage levels and capacities can you handle?","Our team has executed up to 400kV transmission projects (Ruppur–Gopalganj). Sub-station works typically cover 11\u002F33\u002F132kV levels; UPS systems range from 1kVA to 200kVA; generators and solar plants are sized per your load requirement.",{"question":183,"answer":184},"Do you offer Annual Maintenance Contracts (AMC)?","Yes - comprehensive and non-comprehensive AMC options are available for sub-stations, generators, lifts, UPS, solar systems and CCTV. AMCs include scheduled preventive maintenance, 24\u002F7 emergency response and priority spare parts support.",{"question":186,"answer":187},"Which areas of Bangladesh do you serve?","We deliver nationwide - all 64 districts. Our field engineering teams and logistics network are headquartered in Dhaka (Middle Badda, Gulshan Link Road) with regional deployment capability for telecom sites, industrial zones and utility projects.",{"question":189,"answer":190},"What warranty do supplied products carry?","All equipment is OEM-sourced and carries manufacturer warranty (typically 1–5 years depending on product category), backed by ICSTECH installation warranty and our local service team for claims and maintenance.",{"question":192,"answer":193},"How do I get a quotation for my project?","Submit your requirement through the quote form below, call +880 1869-777888, or email info@icstechbd.com with your scope\u002FBOQ. Our engineering team will arrange a site visit if needed and provide a detailed proposal within one business week.",1791319819751]